Skip to main content

Posts

Menard Presuremeter test

 Menard presuremeter test is an in situ stress controlled loading test performed on the wall of the borehole using cylindrical probe which can expand radially. From the readings, stress strain curve can be obtained which yields :  a. the presuremeter modulus  b. the creep presure (yields presure) c. the limit presure (failure presure) Figure A.6.1 shows schematiic diagram of Menard presuremeter test and typical test curves  1.2 Equipment  (1) The Monitoring Unit  Equiped with device to preciesly regulate the presure applied to the probe and read is volume change with presure increment and time. A gas cylinder provides the pressure source. It  includes a 800 cm3 volumeter with sight of tube, a main pressure a regulator , a differential presure regulator, presure gauge 0-2.5 and 0-6 Mpa for the measuring and guard cell (0.06 and 10 Mpa as option for soft soil and weak rock test) and the necesary valves and coupling.  (2) The palstic tubing  Thi...

Berbagai uji test di MRT fase 2

 Untuk menetapkan parameter tanah perlu banyak tes perlu dilakukan untuk memperkirakan parameter yang mumpuni dalam menetapkan angka untuk desain. Tes ada di lapangan juga ada tes di laboratorium.  Kali ini saya akan membahas tes yang dilakukan pada proyek MRT fase 2  Tes Lapangan meliputi : 1. CPTU  2. CPT  3. Geolistrik (Soil Resistivity Measurement) 4. SPT, tipe undisturb sampling : Unditurb soil sampling, piston and Mazier Triple Tube Sampling Method 5. Menard Presuremeter Test is test yang tes in situ yang memperkirakan compresibility of subsoil untuk memperkirakan penurunan gedung tinggi.  6. Downhole seismic Test digunakan untuk memperkirakan menggunakan gelombang suara untuk tujuan klasifikasi jenis tanah . Dari hasil P wave velocity dan S wave velocity dicari dinamic poison ratio dinamis shear modulus dan dinamic young modulus.  7. Standpipe Piezometer Instalation to check graundwater level monitoring dibandingkan dengan pembacaan borelog....

Pecahnya beton girder karena erection

 Setelah erection banyak kerusakan beton semacam ini, dimana beton percast sebagai girder tidak mampu menahan beban tarik dari proses erection. Secara compresive strength beton sudah memenuhi namun tetap terjadi proses seperti ini. Ini terjadi karena efek early strength yang lebih getas penyebabnya beban tarik dari kapasitasnya. Juga diliat dari komposisi dari betonnya dimana course agregrat sangat sedikit di dominasi fine agregrat sehingga beton tidak mengikat walaw compresive strength terpenuhi.  Perbaikan yang mungkin dilakukan kalau retaknya tidak tembus injeksi dan patching mungkin dilakukan. Juga perlu dicermati dalam proses pengakatan perlunya  bentang panjang ngangkatnya harus pake truss holder arau pas saat fabrikasi girder pake perkuatan di sisi pengangkatan. Juga memang jikalau kesalahan jobmix dapat dilakukan Jobmix supaya nambah flexural beton bisa ditambahkan SBR (Styrene Butadiene Rubber), sdh banyak referensinya di negara2 maju.

Arigato gozaimasu Patimban

This April is the last month I worked with Patimban. A lot memory happen from beginning it was a sea the continue to build couseway. Piling at couseway form one pier to ther pier, test pile PDA test and PIT and also start excavation.  Also don't forget to drilling test in bagan at sea.  In Patimban I meet 3 japanese people Atsutsi Kawamura, besso and Tishiko Nishio  1. Drilling at sea  Began in April 2021 and ended at June 2021. Firstly we place bagan at sea according the coordinate. then continue mobilize the drilling machine. A lot problem happen like like sea tide,  difficult to move drilling machine from one bagan to other bagan, machine broken and a lot more. From Abutment one to pier 24 about 1 km. 2. Ramp ON Ramp OFF We built a road in swampy area about 500 m from existing road which built with pile slab in Packet 4.  First install bamboo deep about 5 m then continue with matras bamboo then geotextile next embakment about 1 - 3 m.   3. PDA ...

Penentuan titik- titik penyelidikkan tanah

 Banyak orang kebingungan bagaimana menetukkan titik - titik penyelidikkan tanah yang diperlukan namun  pada SNI 8460  adalah sebagai berikut :

apakah spt nol mempunyai friksi

 ini pernah ditanyakan , mengingat ketika pile dipancang pile meluncur karena tidak ada kekuatan yang menahan. Namun dari uji vane shear didapat su berarti memang ada friksi yang bekerja walaw nilainya kecil. Sehingga dalam mendisain perlu memasukkan friksi karena membantu menahan pile walaw nilainya kecil. 

Sesek sebagai geotextile non woven

 Sesek adalah bambu yang dianyam yang banyak digunakan untruk konstruksi. Berfungsi meratakan beban namun mempunyai kekuatan sangat besar. Mirip dengan geotextile woven namun tradisional. Sangat kuat  crane aja mampu melaluinya. Bisa menurunkan setlement secara merata